Question and scope

Do the lift truck utilization records agree with the charger logs for the same trucks and batteries? The question applies to one operation and a fixed review window, not to a vendor comparison. Utilization records describe when a truck was assigned to work, and charger logs describe when a battery was actually on charge. A gap between them means the fleet report may count a truck as available while its battery is in the charging area.

The test does not decide which system is authoritative for every purpose. Utilization drives labor and equipment planning, while charger logs drive battery rotation and maintenance. The narrow purpose is to measure how often the two records describe the same asset event and to classify the reasons they diverge. A match rate with a stated window and defect count is more useful than a general claim that one system is unreliable.

Why the records diverge

The two records are usually maintained by different teams with different purposes. A fleet system may treat a truck as available until an operator logs off, while the charger log starts when the battery is connected. One record tracks the assignment and the other tracks the asset. Neither is automatically wrong, but the difference has to be visible to the people who use both for planning and for battery replacement decisions.

Battery swaps add a second source of disagreement. A truck can stay in service with a fresh battery while its original battery sits on charge, so the truck and the battery tell different stories. Manual overrides create a third source when a lead closes a truck record to cover a breakdown. The test should name which asset and which clock produced each value before it treats a difference as a behavioral finding.

Population and sample

Begin with a dated export of truck assignments and charger events for the review window. Capture the truck identifier, battery identifier, charger position, shift, assignment start and end, charge start and end, and the person who last edited each record. Keep the query, the export time, and the system names with the file. A later analyst should be able to rebuild the same list without asking which filter was used.

The unit is one truck-and-battery event that should appear in both records. Freeze a sample that covers several truck types, shifts, and charger positions. Record the selection rule before looking at the match results so the sample is not fitted to a favorable outcome. Include trucks that never appear in the charger log, because a missing charge event is one of the defect classes the test is meant to find.

Build match keys before comparing times

Start with the truck identifier and the date, then add the battery identifier as the secondary key. A truck can use two batteries in a day, so the truck alone is not enough. If battery tags are missing or reused, fall back to the charger position plus the shift and record that the fallback was used. Never match on time alone, because two trucks can reach the same charger within minutes and the nearest timestamp may belong to the wrong asset.

Normalize the identifiers before matching: trim spaces, uppercase letters, and remove punctuation that one system stores differently from the other. Record every transformation so the match can be reproduced. Keep unmatched events in their own list rather than dropping them from the denominator. A match rate that silently excludes the hardest records will look better than the operation actually is.

Set tolerance and comparison rules

Decide how close two timestamps must be to count as agreement. A ten-minute tolerance suits many charger logs, but the right number depends on how each system captures time and how often a manual entry replaces a scan. State the tolerance before the test and apply it to every record. Test a second, wider tolerance as a sensitivity check so the reader can see how much the result depends on that choice.

Compare assignment and charge events in the same direction. A charge that starts before the assignment ends may be a legitimate hot-swap, while a charge with no assignment at all may be a truck that was parked. Report the count within tolerance, the count outside tolerance, and the median absolute difference. A single match percentage hides whether the misses are small rounding gaps or events recorded on the wrong day.

Classify the defects

Use a small, fixed set of defect classes so two reviewers can agree. Missing charge record, missing utilization record, duplicate charge event, asset mismatch, time outside tolerance, and wrong date are enough for most operations. Add a class only when a real record cannot fit an existing one. Each defect should point to the system and field that produced it rather than to a person.

Count the classes separately and show them beside the match rate. A high match rate with many duplicates still means the charger data needs repair, while a low rate driven by asset mismatches may be a key problem rather than a timing problem. Review a sample of each class with the person who owns that system. The classification is the part of the test that turns a number into a repair list.

Run the test and check it twice

Have one analyst build the match and a second analyst repeat a subsample from the same export. Record disagreements before resolving them, because two people may apply the tolerance or the fallback key differently. Flag rows where either timestamp was manually entered. Keep the two reviews separate until both are complete so neither analyst anchors the other.

The test is ready when a third person can reproduce the match count from the saved files and the written rules. Save the export, the normalization steps, the match list, the defect counts, and the review notes together. Do not publish a match rate without the window and the tolerance beside it. A reproducible test is more valuable than a precise-looking number that nobody can rebuild.

Interpretation limits

A mismatch does not prove that an operator skipped a charge or that the charger log is wrong. The battery may have been swapped before the assignment ended, the tag may have been entered incorrectly, or a duplicate event may reflect a legitimate reconnect. Read the defect class before drawing a conclusion about behavior. The test describes record agreement, not fault.

Do not use the match rate to rank operators, shift leads, or equipment vendors. Truck mix, battery age, and charger integrations differ across operations, and one integration defect can move the rate for a whole week. Keep the review window and the system versions attached to every number that leaves the team. If the result supports a process change, state the assumption the change depends on and the evidence that would contradict it.

Repair loop

Choose one defect class with a clear owner and fix it at the source. If asset mismatches dominate, add a battery scan at the charger instead of retyping the tag. If duplicates dominate, add a check that rejects a second charge start for the same battery within a short window. Record the change, the owner, and the effective date so the next test can compare like with like.

Repeat the test after the change using the same keys, tolerance, and window length. Compare the defect counts rather than only the headline match rate. A repair that reduces mismatches but increases missing records has moved the problem, not solved it. End the review with one decision and a recheck date. Keep the defect counts beside that decision so the next reviewer can see what changed. The companion battery swap wait measure and battery rotation log show how the same evidence supports equipment and staffing decisions.

Sources

Frequently Asked Questions

Why compare utilization records with charger logs?

The utilization system describes when a truck was assigned to work, while the charger log describes when its battery was actually on charge. Comparing them shows whether the fleet record describes real equipment time.

What tolerance should count as a match?

Set the tolerance before the test based on how each system records time. A ten-minute tolerance suits many charger logs, but the important point is to state it and apply it consistently.

Does a low match rate prove the utilization system is wrong?

No. A low rate may come from swapped batteries, missing asset tags, manual overrides, or charger clock drift. Classify the defects before assigning fault to either record.